Abmessungen
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Alarm
1 relay output with current carrying capacity of 1 A @ 24 VDC
Befestigung
DIN-Rail mounting, Wall mounting (with optional kit)
Betriebstemperatur
-10°C - +60°C (14 - 140°F) / -40 - +75°C (-40 - 167°F)
DIP Switch Funktion
Port break alarm mask
EMC Standards
EN 55022/24
EMI Standards
CISPR 22, FCC Part 15B Class A
EMS Standards
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz, 3 V/m ...
Lagertemperatur
-40 to 85°C (-40 to 185°F)
Luftfeuchtigkeit
5 - 95%, nicht kondensierend
MTBF
255,000 hrs, MIL-HDBK-217F, GB 25°C
Schock und Vibrationen
IEC 60068-2-27, IEC 60068-2-6
Schutzklasse
IP30, UL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nA nC IIC T4 Gc
Sicherheit Standards
UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1
Stabilitäts Test
IEC 60068-2-32 (Free Fall)
Standards & Protokolle
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 80 ...
Strom Anschluss
1 removable 6-pin Terminal Blocks
Strom Anschluss Verpolschutz
Ja
Stromversorgung
24 VDC, redundant dual inputs, 0.22 A @ 24 V
Switch Architektur
Store-and-Forward